Difference between revisions of "Factory Calibration (firmware 2.0)"
(24 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
In the following instructions, commands that need to be done on the Beta are prefixed with | |||
[operator@beta] ~ command | |||
... while commands that need to be done on your computer are prefixed with | |||
$ command | |||
=Notice= | =Notice= | ||
This page is for firmware 2.0. | This page is for firmware 2.0. For firmware 1.0, check this page [[Factory Calibration]]. | ||
For firmware 1.0, check this page [[Factory Calibration]]. | |||
This page is assuming you have installed firmware 2.0 on a microSD card of '''at least 16GB''', in order to capture darkframes on the Beta directly. | This page is assuming you have installed firmware 2.0 on a microSD card of '''at least 16GB''', in order to capture darkframes on the Beta directly. | ||
Line 9: | Line 17: | ||
Hint : create a variable containing your Betas IP for easy access, for example : | Hint : create a variable containing your Betas IP for easy access, for example : | ||
export BETA=192.168.1.101 | $ export BETA=192.168.1.101 | ||
If your startup script doesn't do it already, don't forget to perfom axiom_start.sh | |||
[operator@beta] ~ sudo axiom_start.sh | |||
TO DO | |||
Good practice is to add a "blank snap" when changing exposure timing, ie | |||
[operator@beta] ~ axiom_snap -2 -b -r -e 10ms -z && axiom_snap -2 -b -r -e 10ms > test3.raw12 | |||
---- | ---- | ||
Line 18: | Line 33: | ||
=Preparations= | =Preparations= | ||
Install on your AXIOM Beta: | Install on your AXIOM Beta: | ||
pacman -S python-numpy | [operator@beta] pacman -S python-numpy | ||
For Ubuntu this would look like: | Install the dcraw and octave packages on your PC. For Ubuntu this would look like: | ||
sudo apt-get install dcraw octave | $ sudo apt-get install dcraw octave | ||
Download and compile raw2dng on your PC: https://github.com/apertus-open-source-cinema/misc-tools-utilities/tree/master/raw2dng | Download and compile raw2dng on your PC: https://github.com/apertus-open-source-cinema/misc-tools-utilities/tree/master/raw2dng | ||
Line 37: | Line 49: | ||
On the Beta set gain to x1 by running: | On the Beta set gain to x1 by running: | ||
sudo /usr/axiom/script/ | [operator@beta] ~ sudo /usr/axiom/script/axiom_set_gain.sh 1 | ||
Download this Octave file to your PC into your current work directory: | Download this Octave file to your PC into your current work directory: | ||
wget https://raw.githubusercontent.com/apertus-open-source-cinema/misc-tools-utilities/master/darkframes/read_raw.m | $ wget https://raw.githubusercontent.com/apertus-open-source-cinema/misc-tools-utilities/master/darkframes/read_raw.m | ||
Capture an overexposed image with the Beta and check the levels: | Capture an overexposed image with the Beta and check the levels: | ||
ssh operator@$BETA " | $ ssh operator@$BETA "axiom_snap -2 -b -r -e 100ms" > snap.raw12 <br /> | ||
./raw2dng snap.raw12 --totally-raw<br /> | $ ./raw2dng snap.raw12 --totally-raw<br /> | ||
octave<br /> | $ octave<br /> | ||
octave:1> a = read_raw('snap.DNG')<br /> | octave:1> a = read_raw('snap.DNG')<br /> | ||
octave:2> prctile(a(:), [0.1 1 50 99 99.9]) | octave:2> prctile(a(:), [0.1 1 50 99 99.9]) | ||
Line 67: | Line 79: | ||
Clear the old RCN values, by typing on the Beta : | Clear the old RCN values, by typing on the Beta : | ||
sudo | sudo axiom_start.sh | ||
sudo /usr/axiom/script/ | sudo /usr/axiom/script/axiom_rcn_clear.py | ||
Now you need to make sure that your Beta is not capturing any light (really not a single photon should hit the sensor :) ): | Now you need to make sure that your Beta is not capturing any light (really not a single photon should hit the sensor :) ): | ||
Line 78: | Line 90: | ||
Take 64 dark frames at 10ms (~1.2GB), gain x1 with the following script executed on the Beta: | Take 64 dark frames at 10ms (~1.2GB), gain x1 with the following script executed on the Beta: | ||
sudo /usr/axiom/script/ | sudo /usr/axiom/script/axiom_set_gain.sh 1<br /> | ||
. | axiom_sequencer_stop.sh # disable HDMI stream <br /> | ||
for i in `seq 1 64`; do <br /> | for i in `seq 1 64`; do <br /> | ||
axiom_snap -2 -b -r -e 10ms > dark-x1-10ms-$i.raw12 <br /> | |||
done <br /> | done <br /> | ||
. | axiom_sequencer_start.sh # re-enable HDMI stream | ||
Compute a temporary dark frame for RCN calibration: | Compute a temporary dark frame for RCN calibration: | ||
Line 102: | Line 114: | ||
Set the RCN values: | Set the RCN values: | ||
sudo /usr/axiom/script/ | sudo /usr/axiom/script/axiom_rcn_darkframe.py darkframe-rcn.pgm | ||
Put this in startup script (ie : [[ | Put this in startup script (ie : [[axiom_start.sh]]) : | ||
/usr/axiom/script/ | /usr/axiom/script/axiom_rcn_darkframe.py darkframe-rcn.pgm | ||
==Troubleshooting== | ==Troubleshooting== | ||
Line 123: | Line 135: | ||
Traceback (most recent call last): <br /> | Traceback (most recent call last): <br /> | ||
File "/usr/axiom/script/ | File "/usr/axiom/script/axiom_rcn_darkframe.py", line 75, in <module> <br /> | ||
dark = read_pnm(filename) <br /> | dark = read_pnm(filename) <br /> | ||
File "/usr/axiom/script/ | File "/usr/axiom/script/axiom_rcn_darkframe.py", line 53, in read_pnm <br /> | ||
format, width, height, samples, maxval = png.read_pnm_header( fd ) <br /> | format, width, height, samples, maxval = png.read_pnm_header( fd ) <br /> | ||
AttributeError: module 'png' has no attribute 'read_pnm_header' <br /> | AttributeError: module 'png' has no attribute 'read_pnm_header' <br /> | ||
Line 140: | Line 152: | ||
==Method 1 : on the Beta== | ==Method 1 : on the Beta== | ||
On the Beta, capture one darkframe without compensations: | On the Beta, capture one darkframe without compensations: | ||
[operator@beta] $ sudo /usr/axiom/script/ | [operator@beta] $ sudo /usr/axiom/script/axiom_rcn_clear.py <br /> | ||
[operator@beta] $ | [operator@beta] $ axiom_snap -2 -b -r -e 10ms > dark-check-1.raw12 | ||
Capture one darkframe with compensations: | Capture one darkframe with compensations: | ||
[operator@beta] $ sudo /usr/axiom/script/ | [operator@beta] $ sudo /usr/axiom/script/axiom_rcn_darkframe.py darkframe-rcn.pgm <br /> | ||
[operator@beta] $ | [operator@beta] $ axiom_snap -2 -b -r -e 10ms > dark-check-2.raw12 | ||
Line 170: | Line 180: | ||
---- | ---- | ||
==Method 2 : | ==Method 2 : visual method== | ||
Put a lens cap on the camera and check the image on a HDMI monitor. | Put a lens cap on the camera and check the image on a HDMI monitor. | ||
In the camera set the matrix gains to: | In the camera set the matrix gains to: | ||
<nowiki>[operator@beta] $ sudo /usr/axiom/script/ | <nowiki>[operator@beta] $ sudo /usr/axiom/script/axiom_mat4_conf.sh 20 0 0 0 0 10 10 0 0 10 10 0 0 0 0 10 0 0 0 0</nowiki> | ||
run: | run: | ||
<nowiki>[operator@beta] $ sudo /usr/axiom/script/axiom/ | <nowiki>[operator@beta] $ sudo /usr/axiom/script/axiom/rcn_clear.py</nowiki> | ||
The static noise profile should be visible. | The static noise profile should be visible. | ||
Being in the folder where the darkframe-rcn.pgm file is (should be ~), run: | Being in the folder where the darkframe-rcn.pgm file is (should be ~), run: | ||
[operator@beta] $ sudo /usr/axiom/script/axiom/ | [operator@beta] $ sudo /usr/axiom/script/axiom/rcn_darkframe.py darkframe-rcn.pgm | ||
The static noise profile should be gone. | The static noise profile should be gone. | ||
Line 191: | Line 201: | ||
---- | ---- | ||
==Method 3 : with octave== | ==Method 3 : with octave== | ||
Capture 2 frames: | Capture 2 frames: | ||
ssh operator@$BETA " | ssh operator@$BETA "axiom_snap -2 -b -r -e 10ms" > dark-check-1.raw12 <br /> | ||
ssh operator@$BETA " | ssh operator@$BETA "axiom_snap -2 -b -r -e 10ms" > dark-check-2.raw12 | ||
Convert the two darkframes with raw2dng: | Convert the two darkframes with raw2dng: | ||
Line 228: | Line 234: | ||
=Step 3: Dark frame calibration= | =Step 3: Dark frame calibration= | ||
This step significantly improves image noise levels. More info [https://www.apertus.org/magic-lantern-getting-to-grips-with-axiom-beta-image-sensor-article-feb-2016 here] and [https://www.magiclantern.fm/forum/index.php?topic=11787.msg129672#msg129672 there]. | |||
Make sure the RCN calibration from previous steps is in place before continueing here. | Make sure the RCN calibration from previous steps is in place before continueing here. | ||
Take 400 dark frames at various exposure times for the 4 gains. This will require around 8GB of disk space. | Take 400 dark frames at various exposure times for the 4 gains, and compute darkframes for each gain. This will require around 8GB of disk space. | ||
Script to do it remotely : | Script to do it remotely : | ||
for g in 1 2 3 4 | for g in 1 2 3 4; do <br /> | ||
do <br /> | ssh operator@$BETA sudo /usr/axiom/script/axiom_set_gain.sh ${g} <br /> | ||
ssh operator@$BETA sudo /usr/axiom/script/ | for t in {1..100}; do<br /> | ||
for t in {1..100} | for i in {1..4}; do <br /> | ||
ssh operator@$BETA "axiom_snap -2 -r -e ${i}ms" > dark-x${g}-${t}ms-v${i}.raw12 <br /> | |||
for i in {1..4} | |||
ssh operator@$BETA " | |||
done <br /> | done <br /> | ||
done <br /> | done <br /> | ||
raw2dng --calc-dcnuframe dark-x$g-*.raw12 <br /> | raw2dng --calc-dcnuframe dark-x$g-*.raw12 <br /> | ||
rm *.raw12 <br /> | rm *.raw12 <br /> | ||
done | done | ||
Script to do it on the Beta directly : | Script to do it on the Beta directly : | ||
for g in 1 2 3 4 | for g in 1 2 3 4; do <br /> | ||
do <br /> | sudo /usr/axiom/script/axiom_set_gain.sh ${g} <br /> | ||
sudo /usr/axiom/script/ | for t in {1..100}; do<br /> | ||
for t in {1..100} | for i in {1..4}; do <br /> | ||
axiom_snap -2 -r -e ${i}ms > dark-x${g}-${t}ms-v${i}.raw12 <br /> | |||
for i in {1..4} | |||
done <br /> | done <br /> | ||
done <br /> | done <br /> | ||
raw2dng --calc-dcnuframe dark-x$g-*.raw12 <br /> | raw2dng --calc-dcnuframe dark-x$g-*.raw12 <br /> | ||
rm *.raw12 <br /> | rm *.raw12 <br /> | ||
done | done | ||
This produces the following files: | This produces the following files: | ||
Line 278: | Line 270: | ||
Store these files in a save place as they will be used in post-processing. | Store these files in a save place as they will be used in post-processing. | ||
Place them in the directory where you capture raw12 files or experimental raw HDMI recordings, so raw2dng will use them. | Place them in the directory where you capture raw12 files or experimental raw HDMI recordings, so raw2dng will use them. | ||
Line 283: | Line 276: | ||
---- | ---- | ||
=Dark Frame Validation= | =Dark Frame Validation= | ||
Line 307: | Line 298: | ||
---- | ---- | ||
= | =Color profiling= | ||
Set gain x1. | Set gain x1. | ||
Line 328: | Line 319: | ||
---- | ---- | ||
=Color profiling validation= | |||
= | |||
Render the IT8 chart in Blender, using the OCIO configuration. | Render the IT8 chart in Blender, using the OCIO configuration. | ||
Line 341: | Line 330: | ||
---- | ---- | ||
=Step 5: HDMI dark frames= | =Step 5: HDMI dark frames= |
Latest revision as of 15:44, 18 January 2024
In the following instructions, commands that need to be done on the Beta are prefixed with
[operator@beta] ~ command
... while commands that need to be done on your computer are prefixed with
$ command
1 Notice
This page is for firmware 2.0. For firmware 1.0, check this page Factory Calibration.
This page is assuming you have installed firmware 2.0 on a microSD card of at least 16GB, in order to capture darkframes on the Beta directly.
Hint : create a variable containing your Betas IP for easy access, for example :
$ export BETA=192.168.1.101
If your startup script doesn't do it already, don't forget to perfom axiom_start.sh
[operator@beta] ~ sudo axiom_start.sh
TO DO
Good practice is to add a "blank snap" when changing exposure timing, ie
[operator@beta] ~ axiom_snap -2 -b -r -e 10ms -z && axiom_snap -2 -b -r -e 10ms > test3.raw12
2 Preparations
Install on your AXIOM Beta:
[operator@beta] pacman -S python-numpy
Install the dcraw and octave packages on your PC. For Ubuntu this would look like:
$ sudo apt-get install dcraw octave
Download and compile raw2dng on your PC: https://github.com/apertus-open-source-cinema/misc-tools-utilities/tree/master/raw2dng
3 Check range of the input signal
On the Beta set gain to x1 by running:
[operator@beta] ~ sudo /usr/axiom/script/axiom_set_gain.sh 1
Download this Octave file to your PC into your current work directory:
$ wget https://raw.githubusercontent.com/apertus-open-source-cinema/misc-tools-utilities/master/darkframes/read_raw.m
Capture an overexposed image with the Beta and check the levels:
$ ssh operator@$BETA "axiom_snap -2 -b -r -e 100ms" > snap.raw12
$ ./raw2dng snap.raw12 --totally-raw
$ octave
octave:1> a = read_raw('snap.DNG')
octave:2> prctile(a(:), [0.1 1 50 99 99.9])
If everything worked you will get a wall of numbers now. TODO: We should extract the essential pieces of information here... (min/max maybe)?
Lower numbers should be around 50...300 (certainly not zero). Higher numbers should be around 4000, but not 4095.
Repeat for gains 2, 3, 4.
4 RCN calibration
RCN stands for Row Coloumn Noise correction meaning we filter out the fixed pattern noise.
Clear the old RCN values, by typing on the Beta :
sudo axiom_start.sh sudo /usr/axiom/script/axiom_rcn_clear.py
Now you need to make sure that your Beta is not capturing any light (really not a single photon should hit the sensor :) ):
- close the lens aperture as far as possible
- attach lens cap
- put black lens bag over Beta
- turn off all lights in the room - do this at night or in a completely dark room
Take 64 dark frames at 10ms (~1.2GB), gain x1 with the following script executed on the Beta:
sudo /usr/axiom/script/axiom_set_gain.sh 1
axiom_sequencer_stop.sh # disable HDMI stream
for i in `seq 1 64`; do
axiom_snap -2 -b -r -e 10ms > dark-x1-10ms-$i.raw12
done
axiom_sequencer_start.sh # re-enable HDMI stream
Compute a temporary dark frame for RCN calibration:
raw2dng --no-blackcol --calc-darkframe dark-x1-10ms-*.raw12
This should process quite quickly and output something like the following at the end:
Averaged 64 frames exposed from 12.00 to 12.00 ms.
Could not compute dark current.
Please use different exposures, e.g. from 1 to 50 ms.
Dark offset : 0.00
Writing darkframe-x1.pgm...
Done.
Rename and upload darkframe to your Beta:
mv darkframe-x1.pgm darkframe-rcn.pgm
Set the RCN values:
sudo /usr/axiom/script/axiom_rcn_darkframe.py darkframe-rcn.pgm
Put this in startup script (ie : axiom_start.sh) :
/usr/axiom/script/axiom_rcn_darkframe.py darkframe-rcn.pgm
4.1 Troubleshooting
If you get an error report like this:
Traceback (most recent call last):
File "rcn_darkframe.py", line 17, in <module>
import png
ImportError: No module named 'png'
Make sure the Beta is connected to the Internet (via Ethernet) and run:
pip install pypng
and then run the python script again
If you got something like this :
Traceback (most recent call last):
File "/usr/axiom/script/axiom_rcn_darkframe.py", line 75, in <module>
dark = read_pnm(filename)
File "/usr/axiom/script/axiom_rcn_darkframe.py", line 53, in read_pnm
format, width, height, samples, maxval = png.read_pnm_header( fd )
AttributeError: module 'png' has no attribute 'read_pnm_header'
Make sure the Beta is connected to the Internet (via Ethernet) and run:
sudo pip install --force "pypng==0.0.18"
5 RCN validation
5.1 Method 1 : on the Beta
On the Beta, capture one darkframe without compensations:
[operator@beta] $ sudo /usr/axiom/script/axiom_rcn_clear.py
[operator@beta] $ axiom_snap -2 -b -r -e 10ms > dark-check-1.raw12
Capture one darkframe with compensations:
[operator@beta] $ sudo /usr/axiom/script/axiom_rcn_darkframe.py darkframe-rcn.pgm
[operator@beta] $ axiom_snap -2 -b -r -e 10ms > dark-check-2.raw12
Then use raw2dng to analyze the differences:
[operator@beta] $ raw2dng --no-darkframe --check-darkframe dark-check-1.raw12
[operator@beta] $ raw2dng --no-darkframe --check-darkframe dark-check-2.raw12
With the compensated snapshot the column noise should disappear, and only row noise left should be dynamic (not static). Visual inspection: the dark frame should have only horizontal lines, not vertical ones.
Sample output:
Average : 127.36 # about 128, OK
Pixel noise : 5.44 # this one is a bit high because we only corrected row and column offsets (it's OK)
Row noise : 2.30 (42.2%) # this one should be only dynamic row noise - see Method 3 below.
Col noise : 0.20 (3.8%) # this one is very small, that's what we need to check here
5.2 Method 2 : visual method
Put a lens cap on the camera and check the image on a HDMI monitor.
In the camera set the matrix gains to:
[operator@beta] $ sudo /usr/axiom/script/axiom_mat4_conf.sh 20 0 0 0 0 10 10 0 0 10 10 0 0 0 0 10 0 0 0 0
run:
[operator@beta] $ sudo /usr/axiom/script/axiom/rcn_clear.py
The static noise profile should be visible.
Being in the folder where the darkframe-rcn.pgm file is (should be ~), run:
[operator@beta] $ sudo /usr/axiom/script/axiom/rcn_darkframe.py darkframe-rcn.pgm
The static noise profile should be gone. You will still see dynamic row noise (horizontal lines flickering) - thats expected.
5.3 Method 3 : with octave
Capture 2 frames:
ssh operator@$BETA "axiom_snap -2 -b -r -e 10ms" > dark-check-1.raw12
ssh operator@$BETA "axiom_snap -2 -b -r -e 10ms" > dark-check-2.raw12
Convert the two darkframes with raw2dng:
raw2dng dark-check-*
Make sure you have the required octave function file in place:
wget https://raw.githubusercontent.com/apertus-open-source-cinema/misc-tools-utilities/master/darkframes/read_raw.m
Also you need to install the octave "signal" and "control" packages from: http://octave.sourceforge.net/packages.php then inside octave run to install:
pkg install package_name
To check whether the entire row noise is dynamic, load the two raw images in octave and check the autocorrelation between the two row noise samples:
pkg load signal
a = read_raw('dark-check-1.DNG');
b = read_raw('dark-check-2.DNG');
ra = mean(a'); ra = ra - mean(ra);
rb = mean(b'); rb = rb - mean(rb);
xcov(ra, rb, 0, 'coeff')
Result should be very small (about 0.1 or lower). When running this check on two uncalibrated dark frames, you will get around 0.8 - 0.9.
6 Step 3: Dark frame calibration
This step significantly improves image noise levels. More info here and there. Make sure the RCN calibration from previous steps is in place before continueing here.
Take 400 dark frames at various exposure times for the 4 gains, and compute darkframes for each gain. This will require around 8GB of disk space.
Script to do it remotely :
for g in 1 2 3 4; do
ssh operator@$BETA sudo /usr/axiom/script/axiom_set_gain.sh ${g}
for t in {1..100}; do
for i in {1..4}; do
ssh operator@$BETA "axiom_snap -2 -r -e ${i}ms" > dark-x${g}-${t}ms-v${i}.raw12
done
done
raw2dng --calc-dcnuframe dark-x$g-*.raw12
rm *.raw12
done
Script to do it on the Beta directly :
for g in 1 2 3 4; do
sudo /usr/axiom/script/axiom_set_gain.sh ${g}
for t in {1..100}; do
for i in {1..4}; do
axiom_snap -2 -r -e ${i}ms > dark-x${g}-${t}ms-v${i}.raw12
done
done
raw2dng --calc-dcnuframe dark-x$g-*.raw12
rm *.raw12
done
This produces the following files:
darkframe-x1.pgm, dcnuframe-x1.pgm, darkframe-x2.pgm, dcnuframe-x2.pgm, darkframe-x3.pgm, dcnuframe-x3.pgm, darkframe-x4.pgm, dcnuframe-x4.pgm
Store these files in a save place as they will be used in post-processing.
Place them in the directory where you capture raw12 files or experimental raw HDMI recordings, so raw2dng will use them.
7 Dark Frame Validation
Capture a few new raw12 darkframes with rcn enabled and PGMs in place for raw2dng.
raw2dng --check-darkframe dark*.raw12 > dark-check.log
If the calibration worked you should get lower noise values as in step 2.
average value: close to 128
pixel noise: about 3 or 4 (may increase at longer exposure times)
row noise and column noise should look similar to this:
Pixel noise : 3
Row noise : 1.70
Col noise : 0.15
8 Color profiling
Set gain x1.
ssh root@$BETA "./set_gain.sh 1"
Take a picture of the IT8 chart, correctly exposed.
Edit the coordinates and the raw file name in calib_argyll.sh.
ssh root@$BETA "./cmv_snap3 -2 -b -r -e 10ms" > it8chart.raw12 ./calib_argyll.sh IT8
Save the following files:
- ICC profile (*.icc)
- OCIO configuration (copy/paste from terminal) + LUT file (*.spi1d)
9 Color profiling validation
Render the IT8 chart in Blender, using the OCIO configuration.
Same with the ICC profile (Adobe? RawTherapee? What apps support ICC?)
(todo: detailed steps)
10 Step 5: HDMI dark frames
For experimental 4k raw recording (https://www.apertus.org/axiom-beta-uhd-raw-mode-explained-article-may-2016) step 3 calibration is not required (step 2 should be in place though). Instead darkframes are collected from HDMI recordings.
Record a 1-minute clip with lens cap on.
Average odd and even frames.
(todo: polish and upload the averaging script)
(todo: check if the HDMI dark frames can be computed from regular dark frames)
Results: darkframe-hdmi-A.ppm and darkframe-hdmi-B.ppm.
11 Step 6: HDMI filters for raw recovery
This calibration is for to the recorder, not for the camera. It's for recovering the original raw data from the HDMI, so it has nothing to do with sensor profiling and such.
Record some scene with high detail AND rich colors.
Take a raw12 snapshot in the middle of recording. The HDMI stream will pause for a few seconds.
Upload two frames from the paused clip, together with the raw12 file. This calibration will be hardcoded in hdmi4k.
The two frames must be in the native format of your video recorder (not DNG). You should be able to cut the video with ffmpeg -vcodec copy.
12 TODO
- batch script to copy all the utilities for the workflow
- implement this: https://wiki.apertus.org/index.php/Calibration_files
- automate HDMI calibration