Line 25: Line 25:


==Sensor profiles==
==Sensor profiles==
====Directory structure====


Inside that subdirectory, we can have a '''generic profile''' (one size fits all) and various '''profiles for different setting combinations''' (that can cover either just one particular situation, or can also be generic to some degree):
Inside that subdirectory, we can have a '''generic profile''' (one size fits all) and various '''profiles for different setting combinations''' (that can cover either just one particular situation, or can also be generic to some degree):
Line 38: Line 40:


Or, we may want to test the profile against some validation data, store the results, and pick the profile likely to minimize the calibration errors (some solid math skills required for this one).
Or, we may want to test the profile against some validation data, store the results, and pick the profile likely to minimize the calibration errors (some solid math skills required for this one).
====Sensor calibration files====


'''Inside one profile, we can have the following calibration files''' (all optional; if missing, that calibration step will be skipped):
'''Inside one profile, we can have the following calibration files''' (all optional; if missing, that calibration step will be skipped):


For black calibration:
For [[Black Calibration]]:
 
  beforegain.pgm : static offsets whose source is before the gain amplifiers (that means, will be multiplied by gain, then subtracted)
  beforegain.pgm : static offsets whose source is before the gain amplifiers (that means, will be multiplied by gain, then subtracted)
  aftergain.pgm  : static offsets whose source is after the gain amplifiers
  aftergain.pgm  : static offsets whose source is after the gain amplifiers
Line 48: Line 53:
These 3 files allow computing a dark frame for every gain/expo/temperature combination (at least in theory), and should generalize fairly well to other settings (to be tested).
These 3 files allow computing a dark frame for every gain/expo/temperature combination (at least in theory), and should generalize fairly well to other settings (to be tested).


Other calibration files:
Other calibration files (e.g. [[Response Curves]], [[Pattern Noise]] corrections):
  gainframe.pgm  : per-pixel gain variations
  gainframe.pgm  : per-pixel gain variations
  clipframe.pgm  : clipping offsets (might be changed)
  clipframe.pgm  : clipping offsets (might be changed)

Revision as of 09:58, 26 February 2016

1 Proposal

1.1 Location of calibration files

Store calibration files in a subdirectory (axiombeta-calibration), located in a way similar to dcraw's badpixels file.

dcraw badpixels (from man page):

./.badpixels, ../.badpixels, ../../.badpixels, ...

beta calibration files

./axiombeta-calibration ../axiombeta-calibration ../../axiombeta-calibration

or maybe also ~/axiombeta-calibration ?

1.2 Types of calibration

We will use two types of calibration: sensor profiling (e.g. dark calibration, response curves, all that's needed to get a linear radiometric response) and color profiling (with argyll, for example), so we'll add two subdirectories:

axiombeta-calibration/sensor-profiles
axiombeta-calibration/color-profiles

In theory, these two things (sensor profiling and color profiling) should be independent (if they are not, we probably did a poor job with calibrating the sensor).

1.3 Sensor profiles

1.3.1 Directory structure

Inside that subdirectory, we can have a generic profile (one size fits all) and various profiles for different setting combinations (that can cover either just one particular situation, or can also be generic to some degree):

axiombeta-calibration/sensor-profiles/generic/
axiombeta-calibration/sensor-profiles/gain1_expo1-50/
axiombeta-calibration/sensor-profiles/gain1_expo100-1000/
axiombeta-calibration/sensor-profiles/blacksun8192_expo100-1000/

That means, from all the settings that might affect the calibration, we can build an unique name from the settings that differ from the generic profile. A calibration might cover files at some particular setting value, or some range of values (detected from the supplied input files during calibration).

When selecting a profile, we may want to choose the one with the narrowest setting range that fits the settings of the file being rendered (that one should probably give the lowest calibration errors). If no match is found, the generic profile will be used.

Or, we may want to test the profile against some validation data, store the results, and pick the profile likely to minimize the calibration errors (some solid math skills required for this one).

1.3.2 Sensor calibration files

Inside one profile, we can have the following calibration files (all optional; if missing, that calibration step will be skipped):

For Black Calibration:

beforegain.pgm : static offsets whose source is before the gain amplifiers (that means, will be multiplied by gain, then subtracted)
aftergain.pgm  : static offsets whose source is after the gain amplifiers
darkcurrent.pgm: dynamic offsets dependent on many variables (exposure, temperature, gain), whose scaling factor can be measured from hot pixels (idea from [1])

These 3 files allow computing a dark frame for every gain/expo/temperature combination (at least in theory), and should generalize fairly well to other settings (to be tested).

Other calibration files (e.g. Response Curves, Pattern Noise corrections):

gainframe.pgm   : per-pixel gain variations
clipframe.pgm   : clipping offsets (might be changed)
responseXXXX.pgm: per-pixel response curve data point (raw sensor outputs that should give the corrected value XXXX)
lut.spi1d       : overall or per-channel response curve (shaper)

1.4 Color profiles

Color profiles are stored under this subdirectory:

axiombeta-calibration/color-profiles/

These depend on other things, like ambient light and maybe lens used, so we could think about something like:

axiombeta-calibration/color-profiles/D50/
axiombeta-calibration/color-profiles/Tungsten/
axiombeta-calibration/color-profiles/OsramDulux/                 # model of the light bulbs
axiombeta-calibration/color-profiles/InTheCave/                  # or the location where the calibration was performed
axiombeta-calibration/color-profiles/D50/EF50mm_f/1.8_II/        # from lens metadata

Those variables will be entered manually by the user (or chosen from a pickbox from a GUI), except maybe lens metadata, where it can be obtained from the lens itself (when the lens communication will be functional).

Color profile formats:

- ICC (as saved by argyll)
- config.ocio files?
- ...

2 Wish list

A way to identify which sensor or camera is used (by serial numbers) could be very helpful for those who own more than one camera, or more than one sensor.